Issue 9, 2005

Vapour generation inductively coupled plasma optical emission spectrometry in determination of total iodine in milk

Abstract

Vapour generation inductively coupled plasma optical emission spectrometry (VG-ICP-OES) was used for the determination of the iodine content in milk samples. Modified alkaline ashing of the milk sample was employed for the total digestion of organic matrix constituents. A mixture of potassium hydroxide (2 mL, 2 mol L−1 in ethanol) and calcium nitrate (2 mL, 0.4 mol L−1 in ethanol) was used in the digestion step as an ashing aid for 2 ml of milk sample (or 200 mg of milk powder). Sample ash was then treated with hydrochloric acid (1.5 mL, 5 mol L−1) and sodium sulfite (1.25 mL, 1 mol L−1) for the elimination of carbonates, which would otherwise cause spectral interference. The vapour of elemental iodine was generated by means of oxidation of iodide by hydrogen peroxide (1 mol L−1) in sulfuric acid (5 mol L−1). Using a gas phase separator, matrix elements were completely eliminated; thus the spectral interference of phosphorus (178.222 nm) was removed and the most intense analytical line of iodine (178.218 nm) could be used for determination. The accuracy of the method was verified by analysis of CRM Non-Fat Milk Powder 1549 from NIST, as well as by the comparative study of VG-ICP-OES and ICP-MS results after alkaline solubilization (TMAH 2.5 mL, 10%). The limit of detection for the VG-ICP-OES method is 20 μg L−1 for original milk samples (based on 3σ of blank value). The concentration of iodine in real milk samples was found in the range 0.2–0.8 mg L−1 with a precision of determination from 0.5 to 3.5% (3 replicates).

Graphical abstract: Vapour generation inductively coupled plasma optical emission spectrometry in determination of total iodine in milk

Article information

Article type
Paper
Submitted
01 Apr 2005
Accepted
02 Jun 2005
First published
29 Jun 2005

J. Anal. At. Spectrom., 2005,20, 945-949

Vapour generation inductively coupled plasma optical emission spectrometry in determination of total iodine in milk

E. Niedobová, J. Machát, V. Otruba and V. Kanický, J. Anal. At. Spectrom., 2005, 20, 945 DOI: 10.1039/B504525H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements