Sample introduction systems for reversed phase LC-ICP-MS of selenium using large amounts of methanol—comparison of systems based on membrane desolvation, a spray chamber and direct injection

Author affiliations

Abstract

Three sample introduction systems were compared for their efficiency in introducing a variety of biologically relevant selenium species in organic solutions with the purpose of mimicking the effluent from a chromatographic system. The sample introduction systems consisted of a microconcentric nebuliser (MCN) in combination with a membrane desolvator (MD), a MCN in combination with a cyclonic spray chamber (CS) and a direct injection nebuliser (DIN), respectively. Thirteen selenium standards diluted in 50% methanol were introduced in each system at a flow rate of 50 μl min−1. Except for the selenite and methaneseleninic acid standards that were lost in the MCN-MD system, similar normalized response factors were achieved for the standards regardless of the sample introduction system. When trimethylselenonium and selenate standards were continuously infused in a linear methanol gradient from 10 to 90%, the signal was almost unaffected when the MCN-MD was used as interface. The signals from the MCN-CS introduction system were almost unaffected in methanol concentrations between 10 and 40%, after which they slowly declined. The signal from the DIN showed a plateau in signal intensity at methanol concentrations between 35 and 70%. Detection limits in flow injection analysis, expressed as the concentration that would result in a signal equivalent to three times the peak to peak noise of the baseline, were estimated to be 200, 150 and 100 ng Se L−1 for the MCN-CS, MCN-MD and DIN, respectively. The independence of the signal from the methanol concentration in the eluent allowed quantification of human selenoprotein P isoforms by gradient microbore reversed phase chromatography (μRPC) on the basis of an internal trimethylselenonium standard. The MCN-MD system was applied for μRPC analysis of 77Se enriched yeast samples and more than 30 selenium containing compounds were separated using a linear gradient from 5% to 95% methanol, some of the selenium species eluting in 85% methanol.

Graphical abstract: Sample introduction systems for reversed phase LC-ICP-MS of selenium using large amounts of methanol—comparison of systems based on membrane desolvation, a spray chamber and direct injection

Back to tab navigation

Publication details

The article was received on 11 Oct 2004, accepted on 28 Feb 2005 and first published on 14 Mar 2005


Article type: Paper
DOI: 10.1039/B415717F
Citation: J. Anal. At. Spectrom., 2005,20, 410-416
  •   Request permissions

    Sample introduction systems for reversed phase LC-ICP-MS of selenium using large amounts of methanol—comparison of systems based on membrane desolvation, a spray chamber and direct injection

    L. Bendahl and B. Gammelgaard, J. Anal. At. Spectrom., 2005, 20, 410
    DOI: 10.1039/B415717F

Search articles by author

Spotlight

Advertisements