Analysis of Fe isotopes in sulfides and iron meteorites by laser ablation high-mass resolution multi-collector ICP mass spectrometry

Abstract

The isotopic composition of Fe in iron meteorites and iron sulfides was studied with a UV laser (213 nm wavelength) and a high-mass resolution multicollector-ICP-MS. The long term reproducibility of Fe isotopic measurements was 0.16 and 0.21‰ (2 standard deviations) for δ56Fe and δ57Fe, respectively, i.e., a factor of ∼2 worse than conventional solution analysis. At present the major limitations of precision and accuracy in the laser ablation technique are instrumental mass discrimination (2.0–4.9% per amu) and laser-induced fractionation (up to 4‰ during a single analysis) of Fe isotopes. Laser ablation of iron metal and iron sulfides produces two types of particles: (1) coarse (50–600 nm) spherical and crystalline particles that are isotopically heavier than (2) fine (2–7 nm) amorphous particles. Differential transport of the two types of particles to the ICP can compromise the accuracy of Fe isotope measurements by laser ablation MC-ICP-MS. Despite lower precision compared with solution MC-ICP-MS analysis, the laser ablation technique is capable of resolving Fe isotopic variations between seafloor and sub-seafloor hydrothermal sulfides, and between kamacite and taenite alloys that are commonly present as thin lamellae in iron meteorites. The most important applications of the technique will be for the analysis of small samples where the textural context of the analysed objects is important for the interpretation of Fe isotopic data.

Graphical abstract: Analysis of Fe isotopes in sulfides and iron meteorites by laser ablation high-mass resolution multi-collector ICP mass spectrometry

Article information

Article type
Paper
Submitted
06 Aug 2004
Accepted
07 Jan 2005
First published
31 Jan 2005

J. Anal. At. Spectrom., 2005,20, 192-199

Analysis of Fe isotopes in sulfides and iron meteorites by laser ablation high-mass resolution multi-collector ICP mass spectrometry

J. Košler, R. B. Pedersen, C. Kruber and P. J. Sylvester, J. Anal. At. Spectrom., 2005, 20, 192 DOI: 10.1039/B412169D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements