Issue 1, 2001

Abstract

Personal exposures and microenvironment concentrations of 30 target VOCs were measured for 401 participants living in five European cities as a part of the EXPOLIS (Air Pollution Exposure Distributions within Adult Urban Populations in Europe) study. Measurements in Basel used an active charcoal (Carbotech) adsorbent as opposed to the Tenax TA used in the other study centres. In addition, within each centre, personal and microenvironment VOC sampling required different sampling pumps and, because of different sampling durations, different sampling flow rates. Thus, careful testing of the sampling and analysis procedures was required to ensure accuracy and comparability of collected data. Monitor comparison tests using Tenax TA showed a mean VOC concentration ratio of 0.95 between the personal and microenvironment monitors. The LODs for the target VOCs using Tenax TA ranged from 0.7 to 5.2 µg m−3. The LODs for the 14 target compounds quantifiable using Carbotech ranged from 0.9 to 3.2 µg m−3. Tenax TA field blanks showed no remarkable contamination with the target VOCs, except benzaldehyde, a known artefact with this adsorbent. Thus, the diffusion barrier system used prevented contamination of Tenax TA samples by passive diffusion during non-sampling periods. Duplicate and parallel evaluations of the Tenax TA and Carbotech showed an average difference of <17% in VOC concentrations within the sampling methods, but a systematic difference between the methods (Tenax TA ∶ Carbotech concentration ratio = 1.18–2.36). These field evaluations and quality assurance tests showed that interpretation and comparison of the results in any VOC monitoring exercise should be done on a compound by compound basis. It is also apparent that carefully planned and realised QA and QC (QA/QC) procedures are needed in multi-centre studies, where a common sampling method and laboratory analysis technique are not used, to strengthen and simplify the interpretation of observed VOC levels between participating centres.

Article information

Article type
Paper
Submitted
19 Sep 2000
Accepted
21 Nov 2000
First published
11 Jan 2001

J. Environ. Monit., 2001,3, 159-165

Evaluation of VOC measurements in the EXPOLIS study

J. Jurvelin, R. Edwards, K. Saarela, J. Laine-Ylijoki, M. De Bortoli, L. Oglesby, K. Schläpfer, L. Georgoulis, E. Tischerova, O. Hänninen and M. Jantunen, J. Environ. Monit., 2001, 3, 159 DOI: 10.1039/B007600G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements