Issue 1099, 1967

The determination of aluminium with 8-hydroxyquinoline. Part I. Precipitation in acetate-buffered solution

Abstract

The conditions for an accurate gravimetric or titrimetric determination of aluminium with 8-hydroxyquinoline in acetate-buffered solution have been established. Precipitation is carried out at a pH higher than 5·2 with an excess of 200 to 300 mg of 8-hydroxyquinoline above the stoicheiometric amount in a final volume of 150 to 200 ml, and the precipitate washed with a neutral 0·02 per cent. solution of 8-hydroxyquinoline.

In pure solutions a standard deviation of about 0·01 mg of aluminium has been obtained.

Article information

Article type
Paper

Analyst, 1967,92, 614-617

The determination of aluminium with 8-hydroxyquinoline. Part I. Precipitation in acetate-buffered solution

A. Claassen and L. Bastings, Analyst, 1967, 92, 614 DOI: 10.1039/AN9679200614

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.